Appendix B. Suggested Form for Recording Observations

System Power:  Input voltage __________________________


               Quiescent current ______________________


Sample rate used during checks ________________________


+5 v Regulated Power __________________________________


+12 v Switched Power __________________________________


Operating Current:  Peak ______________________________


                    Intermediate ______________________


                    Base ______________________________


Schmidt Trigger:    Threshold _________________________


                 Triggers on first rising edge?  YES/NO


Transmit Pulse v p-p __________________________________



Analog to digital converter reference voltages:   

                                      + _______________


                                      - _______________